BOLTER

Equipment 0 Comment

Technical specifications of Pneumatic and Hydraulic roof bolting rigs

bolter

  ALMINCO
Gopher
CRAM Wombat FIREFLY INT
Fire Fly
HYDROMATIC
ARO-4000
SIG
HBM 50
ALMINCO
Beaver
Mode of power Pneumatic Pneumatic Pneumatic Hydraulic Hydraulic Hydraulic
Range (m):
smallest (3 Stge)
largest (3 Stge)
0.771 – 1.227
1.374 – 3.657
0.442 – 0.759
1.347 – 3.539
1365 – 3253
1145 – 2793
1500 – 2500
2200 – 3900
725-930 914-1710
1372-3090
Operating air pressure (kPa) 551 -760 551- 758 551- 586 120  
Water pressure operating range
(kPa)
760 – 1240 760 – 1240 689 – 1102 1000-1200 550- 860
Water consumption (l/min.) 15-20
@ 1000 kPa
15-20
@ 1000 kPa
15 – 20 12-40 72- 80
Air consumption at full speed- free
(m3/min)
2.83 -3.4 3.4 – 4.3 at free speed 4.25
Output torque at
stall (Nm)
108 – 136 218 190.4 340 250 – 350 up to 204
Leg thrust /Thrust Feed
kN
6.7 5.1 – 6.97
3.94 – 6.6 (stage 2)
4.00 30
@ 13 789 KPa max.
5.34
Full rotational speed (no load) (rpm) 950 (approx) 960 @ 620 kPa 750 620 200 – 350 525
Machine Weight smallest (kg):
largest (kg):
Three stage 33
42
27.60
46.31
37 74 44-48
Noise level (dB) 84@ free speed 95   98  
No of stages 2 and 3 2 2 2